<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>16009</ErrorNumber>
<ErrorFamily>Image</ErrorFamily>
<ErrorMessage>
IMAGE: Total subscan shift less than zero
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>All</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The net subscan shift is calculated from the following parameters:
</text></DescriptionText>
<DescriptionText><NumberedList>
<ListItem><Text>"set gc sss" - nominal shift, the same for all recorders of the same model</Text></ListItem>
<ListItem><Text>"set gc sssa" - adjustment made during integration</Text></ListItem>
<ListItem><Text>"set mode &lt;mode&gt; sssa" - the workstation can overwrite this shift with a new one for each image</Text></ListItem>
</NumberedList></DescriptionText>
<DescriptionText><text>
If these parameters do not add to be greater than zero, the workstation must have sent a negative shift
which caused the total shift to be less than zero.
</text></DescriptionText>
<DescriptionText><text>
The values of the "gc" parameters should be compared to the factory settings.  If these settings are not the
problem, the source of the negative shift from the workstation should be found and adjusted.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Record error message and contact Creo Service
</text></DescriptionText>
</OperatorAction>
<Cause>
"set gc sss", "set gc sssa", and/or "set mode &lt;mode&gt; sssa" shift parameters are incorrect
</Cause>
<Cause>
Workstation is specifying a large negative shift along the drum.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/gc_cfg_sss.xml</LinkAddress><LinkTitle>NVS: gc sss</LinkTitle></Link>
<Link><LinkAddress>../nvs/gc_cal_sssa.xml</LinkAddress><LinkTitle>NVS: gc sssa</LinkTitle></Link>
<Link><LinkAddress>../nvs/mode_cal_sssa.xml</LinkAddress><LinkTitle>NVS: mode sssa</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:27 2008 PST
</Updated>
<Links>
</Links>
</Error>